Real Openness and Some New OPC Glue Enable Industrial Network Interoperability

ControlDeisgn.com

By Paul Miller and Joe Feeley, Editor in Chief

Truly open networking solutions are important to both end user and manufacturer.

For the user, an open solution allows selection of best-in-class components, since many suppliers will try to provide additional, unique features that make them stand out.

“Since the connectivity and communication level is well-defined, these differences tend to focus on true usability enhancements like better LEDs, additional diagnostics via LCD displays or higher quality housings and connectors,” says Helge Hornis, Ph.D., manager, intelligent systems, Pepperl+Fuchs. “Because a truly open networking solution allows the relatively easy exchange of one manufacturer’s product with those from another manufacturer, end users gain a level of security and long-term availability simply not possible with proprietary equipment.”

There are reasons why manufacturers favor open solutions, too. “A well-defined open solution makes strictly defined interoperability testing a part of the device requirements,” adds Hornis. “This means that products for all participating vendors will work together.” That’s another advantage for the user.

Sometimes, however, interoperability needs some assistance. The new direction that OPC UA takes should help with that.

The next generation of integration standards from the OPC Foundation, OPC Unified Architecture (UA), abandons the Microsoft–based structure of its much-criticized, DCOM-based, OPC DA predecessor and embraces open, vendor-independent Web Services. OPC UA ties together functions from earlier OPC specifications—data access (DA), historical data access (HDA) and alarms & events (A&E)—and enables a common services-oriented architecture (SOA) environment.

The backward-compatible OPC UA looks to cross-platform interoperability and supports a much richer set of data and information.

The initial OPC UA specs were released to early adopters in 2006 and the first OPC UA-enabled products just now are beginning to hit the market.

Most of the OPC UA questions the OPC Foundation receives from users and automation vendors address problems with existing OPC products, says Jim Luth, OPC Foundation technical director. “This includes getting rid of DCOM, which is difficult to configure and has firewall issues,” he adds. OPC UA, says Luth, is built on Internet protocol (IP) technology. “UA is designed to be both cross-platform and transportable,” he states. “You’ll see UA in devices and places where you’d never see DCOM-based applications.”

With industrial networking technologies from OPC, PNO, HART, FF and FDT all coming together, factory automation is the next target. “Once we add on the capabilities of DeviceNet, ControlNet and EtherNet/IP, we’ll essentially have one way for doing configuration, diagnostics and run-time operation for any device, regardless of the network it’s on,” says Tom Burke, OPC Foundation president.

The foundation aims to have a robust third-party compliance program in place before UA products ship in any quantity. A new independent certification test lab at Ascolab’s main facility in Erlangen, Germany, is staffed by experienced designers and developers of OPC certification tools, says Burke. The program means users should expect reduced installation costs and products that perform reliably in multi-vendor installations.

Since UA involves a richer information set, across plant networks and between plant and enterprise networks, it will be important to follow best practices for networked applications.

“We’ll have to design networks that route the information where and when it’s needed,” says Stephen Briant, product manager at Rockwell Automation. “We need to use best practices to prevent unintended devices or packets from showing up on our wires. I don’t see best practices, relative to firewalls, traffic limitations and so on, changing all that much. We need to consider the impact that new, open devices will have on network design to assure that it remains performant and secure.”

Barriers between engineers and IT personnel actually might come down. “The goal is to keep things simple enough so points of confrontation don’t develop,” comments Keith Jones, product marketing manager at Wonderware. “Examples can include opening ports, firewalls or user accounts. OPC UA addresses these points of conflict by being easy to engineer, performant and interoperable. The OPC UA discovery service, for example, helps monitor network performance. UA also is very easy to connect into PLCs, alarming applications, ERP systems and the like.”

Want MoreMORE ON UA VS. DA
For an expanded look at UA vs. DA, browse to a two-part article on the subject.
- Have More Data Conversations
- Have More Data Conversations—Part II


More Voices

Open Network Options
08/20/2008
Real Openness and Some New OPC Glue Enable Industrial Network Interoperability

Panels Get Size and Heat Under Control
07/08/2008
Machine Builders’ Space and Heat Restrictions Dictate Panel Requirements

Sense a Presence
06/30/2008
Sensors Are Used In Applications Where Automated Machinery or Processes Need to Be Synchronized or Controlled

Solid-State Relays Enhance Reliability
05/09/2008
SSRs and PLCs Have Changed Over the Years. Find Out How

Technology Spurs Touchy Situations
04/18/2008
Analog Resistive Touchscreens Allow the Use of Covered Hands, Such as Gloves and Other Devices

A Switch in Time
04/06/2008
The First Programmable Limit Switch (PLS) Was Resolver-Based because of Encoder Limitations in High-Vibration Environments

Make Controls Kaboom-Proof
03/04/2008
Purged or Pressurized Enclosures Require Constant Pressure From Inert Gases, Which Could Leak or Become Over-Pressurized

Machine Vision Takes a Global Look
02/12/2008
Complex Inspection and Error-Proofing Applications Have Traditionally Required Expensive Components That Are Difficult to Install and Use

Layers Protect Access to Controls
01/02/2008
Unfortunately Passwords Get Passed Around. Access in the Wrong Hands Often Leads to Machine Downtime, Costing Thousands

It’s Not Easy Being Blue
10/31/2007
“Bluetooth has a straightforward infrastructure, adapts to frequency-hopping, copes well with interference and is more agile than ZigBee.”

Color Sensor Selection
10/04/2007
Color sensors vary in range of capability from looking for a specific color at a specific location to looking for multiple colors anywhere in a field of view.

Protect Your Flank
09/11/2007
Machine builders, like many military strategists, often struggle with the logistics and resource costs of protecting the flank.

When RTOS Really Is Needed
08/01/2007
Real Time Operating systems (RTOSs) require machine builders and integrators to make choices regarding their use.

Customize your software?
06/04/2007
Our TechFlash focus this month offers suggestions on newer software tools that let builders rely on off-the-shelf software to do their HMI customization. Contributing Editor Loren Shaum reports.

Manage diagnostic data
05/10/2007
This is an excerpt from reliability expert Daryl Mathers’ article at ControlDesign.com’s sister site PlantServices.com. It provides a practical end-customer viewpoint on diagnostics and troubleshooting.

Advances in handheld HMI
04/12/2007
With the expanded capabilities of handheld HMIs, the functionality of built-ins can be obtained, but with some portability and less cost. Read how in this latest installment of Tech Flash.

Eliminate arc-flash hazard
03/08/2007
Much-too-common close calls, combined with NFPA 70e requirements, create a need to move as many maintenance functions as possible outside of electrical enclosures.

The role of the ODM
01/03/2007
System integrators tend to have a good understanding of component technologies but a lesser understanding of the unique characteristics of an individual OEM market. Read why in this month's installment of TechFlash.

In search of encoder accuracy
01/01/2007
As the technology has improved, encoders have become the dominant rotary and linear displacement measurement means. Today it dominates North America and Asia, while resolvers still hold Europe.

Data acquisition can be simple
09/12/2006
Compact data loggers have been around for years, but recent technical advances and open standards have cut costs and eased use. Senior Tech Editor Dan Hebert, PE, reports in this installment of TechFlash.

Show us your RTOS
08/09/2006
An informal poll of Machine Builder Nation shows most respondents in all operating system speed classes say they’re largely satisfied with their stated OS performance, or at least satisfied enough for now.

ECAD software enables innovation
06/21/2006
This installment of TechFlash introduces readers to new innovations in ECAD technology that could lead to complete virtual design, build, and machine commissioning before a system is constructed.

Flow simulation finds failures, tunes systems
05/10/2006
Several flow simulation packages are available to solve problems in everything from injection molding to designing hydraulic and pneumatic controls. So, don’t build and break prototypes. Instead, simulate the problem.

X-Y motion: Meters to nanometers
02/16/2006
Contributing columnist Wayne Labs takes a look at how multi-axis motion applications at both the macroscopic and microscopic levels are benefiting from the latest advances in x-y positioning systems.

Pass it on: Relaying PLC messages
01/26/2006
This month's TechFlash column reviews the latest advances in relays, and why the programmable varieties in particular retain popularity with control system designers.

Analog I/O: connected but safely isolated
01/16/2006
Today’s analog I/O device vendors are giving industrial I/O builders functionality that includes Ethernet communication, digital and capacitive isolation, built-in sensors and new levels of configurability.


Free Subscriptions

Control Design Digital Edition

Access the entire print issue on-line and be notified each month via e-mail when your new issue is ready for you. Subscribe today.